Keranjang
Login / Register

350 kVA Cummins NTA 855 G4 Diesel Generator Set

Price
Request a quote

The supplier does not display a price for this product. Click Request Quotation to get the best price.

Country of Origin
Indonesia
Shipped From
Cikupa, Tangerang
Category
Mini Generator
Last Updated
26 Oct 2026

Specifications of 350 kVA Cummins NTA 855 G4 Diesel Generator Set

Explore a wide selection of Mini Generator.

Premier Heavy-Duty Industrial Power Solution: 350 kVA Cummins NTA 855 G4 Diesel Generator Set



A Strategic Investment for Continuous and Efficient Business Operations

Maintaining an uninterrupted electrical power supply is the cornerstone of operational efficiency and profitability in modern industrial facilities. Unexpected power outages from the main grid disrupt production lines, risk severe damage to high-value machinery, and jeopardize customer commitments. The 350 kVA diesel generator set driven by the heavy-duty Cummins NTA 855 G4 industrial engine offers an engineered solution designed to deliver absolute electrical security. This robust generator set reliably delivers a continuous prime power output of 350 kVA / 280 kW and a standby reserve capacity of 385 kVA with exceptional precision and consistency.

Driven by a massive 14.0-liter six-cylinder engine featuring advanced turbocharged aftercooled technology, this unit ensures manufacturing plants, commercial towers, data facilities, and critical job sites operate at peak performance. PT Multi Kharisma Prima supplies this equipment in three versatile casing configurations: Open Type for indoor engine rooms, Silent Type for noise-sensitive surroundings, and Mobile Type for dynamic field site mobility.



PT Multi Kharisma Prima: Your Trusted Professional Industrial Power Partner

As a leading generator distributor and power engineering provider in Indonesia, PT Multi Kharisma Prima is committed to supplying genuine diesel generator sets sourced directly from authorized manufacturers, backed by official warranties and quality assurances. We recognize acquiring a generator set represents a long-term capital investment. Our experienced sales engineers and technical specialists offer guidance encompassing initial electrical load audits, system integration planning, nationwide logistics delivery, professional installation, and site acceptance load testing.

Our after-sales ecosystem provides peace of mind through ready-stock genuine spare parts and responsive field technicians available for preventative maintenance and servicing. Discover our track record, corporate credentials, and quality assurances on our Company Profile page.



Detailed Technical Specifications of 350 kVA Cummins Diesel Generator

Specification Parameter Detailed Industrial Technical Data
Prime Power Output Rating 350 kVA / 280 kW
Standby Power Output Rating 385 kVA / 308 kW
Industrial Engine Brand & Model Cummins NTA 855 G4
Cylinder Architecture 6 Cylinders Inline, 4-Stroke
Bore x Stroke 140 mm x 152 mm
Total Engine Displacement 14.0 Liters (14,000 cc)
Aspiration & Cooling System Turbocharged & Aftercooled, Radiator Cooled (Water Cooled)
Governor System Precision Mechanical / Electronic Governor
Electrical Voltage & Frequency 3-Phase 220V/380V (400V/230V Option), 50 Hz
Rated Electrical Current Approx. 531.8 Amps
Power Factor 0.8 Lagging
Alternator Brand & Type Stamford / Brushless Alternator (Class H, IP23)
Automatic Voltage Regulator (AVR) Precision AVR (±1% Regulation Tolerance)
Digital Control Module Deepsea / SmartGen Digital Controller
Fuel Consumption (75% Load) 56.00 Liters / hour
Fuel Consumption (100% Load) 75.00 Liters / hour
Engine Oil Capacity 38.6 Liters
Electric Starting System DC 24V Starter Motor & Heavy-Duty Batteries
Noise Level (Silent Type) Approx. 73–75 dBA at 7 meters
Casing Configuration Options Open Type, Silent Type, Mobile Type



Casing Variants, Physical Dimensions, and Fuel Tank Analysis

PT Multi Kharisma Prima engineers each generator casing option to optimize footprint efficiency, service accessibility, and field transportability. The table below outlines physical dimensions and daily fuel tank capacities for each configuration:

Configuration Type Physical Dimensions (L x W x H) Net Weight Daily Fuel Tank Capacity
Open Type 3200 mm x 1150 mm x 2600 mm 3112 kg 400 Liters
Silent Type 4510 mm x 1510 mm x 2100 mm 4320 kg 450 Liters
Mobile Type 4510 mm x 1510 mm x 2100 mm 4320 kg 450 Liters



Key Characteristics of Premium Casing Construction

Every casing option for the 350 kVA Cummins generator is manufactured to high precision standards, ensuring maximum mechanical protection in demanding work environments:

  • Open Type: Ideal for stationary indoor installations within dedicated engine rooms (power houses). Built upon a heavy-duty steel skid frame equipped with anti-vibration mountings, this design facilitates connection to exhaust silencer systems and acoustic room ventilation ducting. The integrated 400-liter base tank supports extended running periods.
  • Silent Type: Engineered specifically for outdoor deployment and noise-sensitive operating environments. The canopy is constructed from heavy-gauge steel insulated with fire-retardant Soundproof Foam. Finished with electrostatic Powder Coating for resistance against corrosion and extreme weather, it suppresses noise levels down to 73–75 dBA at 7 meters. Features an integrated 450-liter daily fuel tank.
  • Mobile Type: Designed for projects requiring power mobility across job sites, such as construction, mining, and rental applications. It mounts the Silent Type canopy onto a heavy-duty four-wheel trailer chassis equipped with handbrakes, leaf spring suspension, tail lights, and a standard towing bar. Includes a 450-liter fuel tank.



Engineering Features of the Cummins NTA 855 G4 Industrial Engine

The high-output Cummins NTA 855 G4 engine provides unmatched durability and power density for this 350 kVA generator set:

Massive 14.0-Liter Engine Displacement: The 6-cylinder inline engine block (140 mm bore and 152 mm stroke) yields high low-end torque. This large displacement allows the engine to absorb sudden electrical starting loads (inrush currents) when starting heavy industrial motors.

Optimized G4 High-Output Calibration: The NTA 855 G4 model uses optimized fuel injection and aftercooled air intake calibrations to produce 350 kVA / 280 kW power output while maintaining overall engine durability.

Fuel Economy: Consuming 56.00 liters per hour at 75% load and 75.00 liters per hour at 100% full load, the engine maintains a predictable fuel consumption rate for operational budgeting.

Serviceability and Global Spare Parts Support: Proven NTA 855 engine design simplifies routine service procedures. Supported by an established Cummins distribution network, maintenance components remain readily available across Indonesia.



High-Precision Alternator and Electrical Output

The industrial Cummins engine is paired with a Stamford / brushless alternator, producing clean and stable electrical power for sensitive facility equipment.

Equipped with an Automatic Voltage Regulator (AVR), the alternator maintains voltage regulation within a tight ±1% tolerance. This prevents voltage surges, sags, and harmonic distortions affecting computers, automated control systems, and machinery. The alternator features Class H thermal insulation rated up to 180°C and an IP23 protection enclosure against dust and moisture.



Digital Control Module and Automated Safety Features

Operation of the 350 kVA Cummins generator is managed by an advanced digital control panel (Deepsea / SmartGen) featuring an intuitive graphical display. The controller monitors key system parameters in real time:

  • Comprehensive Electrical Parameters: Displays phase-to-phase and phase-to-neutral voltages, electrical current (Amps), frequency (Hz), power factor (Cos Phi), active power (kW), and cumulative energy consumption (kWh).
  • Real-Time Engine Monitoring: Monitors oil pressure (38.6-liter oil capacity), coolant temperature, engine RPM, battery charging voltage, and cumulative running hours.
  • Automatic Protection Shutdown: Protects the generator by initiating automatic shutdown upon detecting abnormal conditions such as low oil pressure, high coolant temperature, overspeed, battery charging failure, or electrical overload.
  • ATS/AMF Integration: Ready for connection with Automatic Transfer Switch (ATS) / Automatic Mains Failure (AMF) panels to automatically start the generator during main grid power failures and transfer electrical loads.



Standard Package Inclusions

Every 350 kVA Cummins generator purchased from PT Multi Kharisma Prima is supplied as a complete operational package including standard industrial accessories:

  • Complete integrated generator unit with Cummins NTA 855 G4 engine and Stamford alternator.
  • Digital control panel module mounted to the generator frame.
  • DC 24V starting batteries complete with connecting cables and battery rack.
  • Industrial exhaust silencer muffler with flexible expansion joint piping.
  • Integrated daily fuel tank built into the base skid frame.
  • Standard maintenance toolkit, operational manuals, and factory test certificates.



Quality Testing and Factory Acceptance Testing

PT Multi Kharisma Prima enforces quality assurance protocols prior to shipment. Every generator set undergoes a Factory Acceptance Load Bank Test across 25%, 50%, 75%, 100%, and 110% load steps.

This procedure verifies radiator cooling performance, fuel combustion efficiency, governor speed response, and alternator voltage stability against factory specifications before site delivery.



Industrial and Commercial Applications

With its 350 kVA / 280 kW power rating, this Cummins diesel generator set serves as a prime or standby power supply across key commercial and industrial sectors:

  • Manufacturing & Processing Plants: Supplies stable electrical current for automated production lines, heavy electric motors, processing machinery, and industrial compressors.
  • Commercial Buildings & Public Facilities: Maintains continuous power for lighting, elevators, escalators, and HVAC systems in office towers, shopping malls, hotels, and financial institutions.
  • Construction & Mining Operations: Delivers autonomous power at remote job sites for welding equipment, field lighting, and site offices.
  • Hospitals & Data Centers: Ensures uninterruptible power for critical life-support medical systems and enterprise servers.



Frequently Asked Questions (FAQ)

Technical answers to common questions regarding the 350 kVA Cummins generator set:

  • What is the actual continuous load capacity in kW for this 350 kVA generator set?
    The 350 kVA generator set delivers a rated prime capacity of 280 kW (280,000 Watts) at a 0.8 power factor. For optimal fuel economy and engine longevity, continuous running loads should be kept between 70% and 80% of total rating (approx. 196 kW to 224 kW).
  • What is the hourly fuel consumption rate?
    Fuel consumption for the Cummins NTA 855 G4 engine is approximately 56.00 liters per hour at 75% load and 75.00 liters per hour at 100% full load.
  • What is the primary difference between Cummins NTA 855 G4 and NTA 855 G1B models?
    The NTA 855 G4 model is calibrated specifically to yield a higher 350 kVA / 280 kW output rating, whereas the G1B model operates at 325 kVA / 260 kW from the same 14.0-liter displacement engine block.
  • Is this generator set compatible with an automatic ATS panel?
    Yes, the digital controller is fully compatible with Automatic Transfer Switch (ATS) / Automatic Mains Failure (AMF) panels for automated grid-to-generator power switching.
  • How often should routine maintenance be performed?
    Routine servicing, including engine oil (38.6 liters capacity), oil filter, and fuel filter replacements, is recommended every 250 running hours or every 6 months. Additional technical guidance is available on our FAQ page.



Technical Installation and Preventative Maintenance Guidelines

Proper installation requires a reinforced concrete foundation pad capable of supporting the unit weight (up to 4320 kg for Silent Type), adequate airflow ventilation for intake and radiator discharge, and correctly routed exhaust piping. Preventative maintenance includes daily checks of engine oil levels, air filter cleaning, water separator draining, and battery voltage checks. Read detailed technical articles on our Genset Articles page.



Official Warranty and After-Sales Support

PT Multi Kharisma Prima backs every purchase with official manufacturer warranties, genuine spare parts availability, and field engineering support. Browse alternative generator capacities on our Genset Catalogue page, or view our complete industrial power lineup on our Product Catalogue page.



Contact Us for Official 350 kVA Cummins Generator Quotations

Ensure reliable power for your business operations with the 350 kVA Cummins generator from PT Multi Kharisma Prima. Contact our sales engineering team today for load consultations, stock availability, and competitive quotations. Visit our Contact Us page to connect directly with our representatives. We manage supply, delivery, and commissioning support across Indonesia.

Can't find the product you're looking for?Request a quotation now

Company Details

Founded In
2021
Business Field
-
Number of Employees
3
We Sell
Genset
Address
Pergudangan Bizpoint Boulevard, Kel. Sukamulya, Kec. Cikupa, Kab. Tangerang, Banten, Indonesia 15710
Suka Mulya, Cikupa, Tangerang, Banten

Company Profile

PT. Multi Kharisma Prima merupakan perusahaan yang menjual kabel untuk kebutuhan proyek pembangunan gedung: RS, Hotel, Stadion, Apartemen, Sekolah, Supermarket, Mall, Pabrik Dll.

More Products From PT Multi Kharisma Prima

Full catalog

More Products