Sell Woodward XE2 – DC current relay for loss of excitation protection from Indonesia by Sumber Berkat Abadi,Cheap Price

Woodward XE2 – DC current relay for loss of excitation protection

Rp29.999.000
  • Minimum Order 1 unit
  • Country Origin Germany
  • CategoriesCurrent Relay
  • Last Updated02 Sep 2018

Product Specification Woodward XE2 – DC current relay for loss of excitation protection

Woodward XE2 – DC current relay for loss of excitation protection

Technical data
Measuring input circuits Rated frequency: 0 - 300 Hz Thermal withstand capability in current circuit: during 10 s 5 x In continuously 2 x In Power consumption in current path: at In = 10 A 0,2 VA Exciter current measuring: Rated exciter current In: 10 A DC (measuring range up to 17 A DC) Power consumption in measuring path: <1 VA Auxiliary voltage Rated auxiliary voltage Uv/ Power consumption: 19 - 390 V DC or 36 - 275 V AC (f = 40 - 70 Hz) 4 W (terminals A1-A2) Maximum interruption time UV = 24 V DC: tu = 8 ms, UV = 48 V DC: tu = 35 ms of auxiliary voltage tU UV > 60 V DC: tu = 50 ms Common data Dropout to pickup ratio: >95 % Resetting time from pickup: <40 ms Returning time from trip: 500 ms Minimum initialization time after supply voltage has applied: 200 ms Minimum response time when supply voltage is available: <120 ms Output relay Number of relays: 2 Contacts: 1 changeover contact for each trip relay Maximum breaking capacity: ohmic 1250 VA / AC resp. 120 W / DC inductive 500VA / AC resp. 75 W / DC Maximum rated voltage: 250 V AC 220 V DC ohmic load Imax = 0,2 A inductive load Imax = 0,1 A at L/R ≤ 50 ms 24 V DC inductive load Imax = 5 A Minimum load: 1 W / 1 VA at Umin ≤ 10 V Maximum rated current: 5 A Making current (16ms): 20 A Contact life span: 105 operations at max. breaking capacity Contact material: AgCdO System data Design standard: VDE 0435 T303; IEC 0801 part 1-4; VDE 0160; IEC 255-4; BS142; VDE 0871 Temperature range at storage and operation: - 25°C to + 70°C Constant climate class F acc. DIN 40040 and DIN IEC 68, part 2-3: more than 56 days at 40°C and 95 % relative humidity

Price Woodward XE2 – DC current relay for loss of excitation protection

: Rp29.999.000
SUMBER BERKAT ABADI Our Specialist provides :1. Auto Synchronous Generator = Woodward, Smartgen, ComAp, Datakom Speed Control & Actuator = Woodward, GAC, Segma, Cummins2. Battery Charger = BAE, SEG, Smartgen BAC, CSS, Aspire, Datakom SMPS & Firetrol3. AVR = Stamford, Leroy Somer, Marrelli, Mecc Alte, Taiyo, Basler, Caterpillar, OEM4. VDO Gauge & VDO Sender5. Turbocharger = Holset, Garrett, KMP, Perkins, IHI, Mitsubishi, Caterpillar6. Relay Protection, Overcurrent, Overvoltage & Trafo = Broyce Control & SEG7. Solenoid & MPU = Woodward, HEL, Deutz, Kubota, DENSO, OEM8. Stater Motor & Alternator = Bosch, Mahle, Iskra, Delco Remy, Hitachi, OEM COS = Smartgen & Kyoritsu9. Fuse MV = SIBA, Bussmann, Schneider, Siemens10. Spare Parts Generator = Cummins, Komatsu, Perkins, Deutz, Caterpillar, Yanmar & Kubota11. Undercarriage Excavator12. Potensiometer, Dioda, Switch, Connector = Vishay Spectrol, BournsHP / WA : 08788-24-000-19 Mr. Sonny Pranata

We Sell
  • Woodward
  • Battery Charger Bae
  • Seg
  • Avr
  • Cos

Dapatkan penawaran terbaik untuk
Woodward XE2 – DC current relay for loss of excitation protection !

Nama
Quantity
Unit
Request Quote
We are an Online Media that consists of Distributors, Resellers, Manufactures, Suppliers, importers and exporters. If you are interested to buy Woodward XE2 – DC current relay for loss of excitation protection cheap, please contact the Company directly.

If you are a Company who wished to sell your product,
Contact Supplier
Sumber Berkat Abadi

4 Year
Response Rate :
100%
Jl. Pintu Air 3 No.25-C Pasar Baru - Jakarta Pusat Jakarta Pusat, DKI Jakarta - Indonesia

Other Companies Related to

PT Mandiri Raya Tangguh

Verified Supplier
Indotrading gold member
4 Year
Response Rate 100%

Surya Tech

Verified Supplier
Indotrading gold member
6 Year
Response Rate 100%

PT Aneka Electrindo Nusantara

Verified Supplier
Response Rate 100%
Arrow