Product Specification PINGUIN TANK

type
capacity
Wall thickness
Inlet
outlet
drain
 

TB-Speks-32 2TB-Speks-33 2TB-Speks-53 2TB-Speks-55 2TB-Speks-70 2TB-Speks-80 2TB-Speks-110 2TB-Speks-120 2TB-Speks-160 2TB-Speks-200 2 TB-Speks-220 2TB-Speks-300 2TB-Speks-400 2TB-Speks-500 2TB-Speks-800 2
TB 32TB 33TB 53TB 55TB 70TB 80TB 110TB 120TB 160TB 200 TB 220TB 300TB 400TB 500TB 800
300 ltr300 ltr520 ltr520 ltr650 ltr800 ltr1.050 ltr1.200 ltr1.550 ltr2.000 ltr 2.250 ltr3.100 ltr4.100 ltr5.100 ltr8.000 ltr
4 - 6 mm4 - 6 mm6 - 9 mm6 - 9 mm7 - 10 mm7 - 10 mm9 - 11 mm9 - 11 mm10 - 12 mm10 - 12 mm 10 - 12 mm10 - 15 mm12 - 18 mm12 - 18 mm15 - 20 mm
¾ inch¾ inch¾ inch¾ inch¾ inch¾ inch1 inch1 inch1 inch1½ inch 1½ inch1½ inch2 inch2 inch2 inch
¾ inch¾ inch¾ inch¾ inch¾ inch¾ inch1 inch1 inch1 inch1½ inch 1½ inch1½ inch2 inch2 inch2 inch
--¾ inch¾ inch¾ inch¾ inch¾ inch¾ inch1 inch1 inch 1 inch1 inch1½ inch1½ inch1½ inch

 

Installation Method


Installation Guide /  Water Tank Installation
Application Instructions tank placement / foundation

The foundation is made ​​well and is very important for all of the water tank. Every 1000 liters of water weighs 1 ton, so it is important to consider the manufacturing foundation that can withstand the weight of the entire tank.

     Types of laying the tank:
         Tower made ​​of metal frame that is not pedestal base there are gaps in the tank.
         Tower made ​​of reinforced concrete
         Dak of reinforced concrete
         The ground floor of reinforced concrete or masonry wall
     The foundation for the tank base must be clean, flat, meetings and flat (water level)
     Placement location to build a solid foundation to be in stable condition
     The width of the foundation should be larger than the diameter of the tank.
     Do not put a water tank on top of the installation of piping and / or buried cable that may require servicing or maintenance.
     Placement location of the tank to avoid areas / locations coined mobility and passing a crowded
     Do not install the water tank on top of underground structures such as sheds, septic tanks, sewer, etc.

General Tanks are not designed for underground installation. It can not be suppressed fully / partially
Surface Stand / Foundations
tb tb-foundation-foundation-ok-bad
Installation of the tank - the pump

Polyethylene tanks have a tolerance limit for elastic expansion / shrinkage is 3% of the dimensions of the tank. All tank connections should have a provision that allows movement when the tank expands / shrinks due to changes in temperature and load.

     Use the pump according to the required pressure.
     Pump put into place that is easy to be checked if a problem occurs.
     Place the pump as close to the water source, due to the far distance of the suction pipe (suction) pipe will add power thrust (discharge).
     Installation of the pump must not be directly or close to the tank outlet.
     Use flexible connections to protect the walls of the tank from the pump vibration. See the picture
     Pumps must be bound (the screw) strong on the stand, to avoid movement and vibration when the pump is operating.
     Reduce the number of bends in the pipe joints to prevent leaks in plumbing installation and minimize energy barriers.
     Attach the Sand Sieve (strainer) for an easy source of water sucked dirt.

 

The surface Stand / Foundations

tb-pondasi-oktb-pondasi-bad

Installation of the tank - the pump

Polyethylene tanks have a tolerance limit for elastic expansion / shrinkage is 3% of the dimensions of the tank. All tank connections should have a provision that allows movement when the tank expands / shrinks due to changes in temperature and load.

     Use the pump according to the required pressure.
     Pump put into place that is easy to be checked if a problem occurs.
     Place the pump as close to the water source, due to the far distance of the suction pipe (suction) pipe will add power thrust (discharge).
     Installation of the pump must not be directly or close to the tank outlet.
     Use flexible connections to protect the walls of the tank from the pump vibration. See the picture
     Pumps must be bound (the screw) strong on the stand, to avoid movement and vibration when the pump is operating.
     Reduce the number of bends in the pipe joints to prevent leaks in plumbing installation and minimize energy barriers.
     Attach the Sand Sieve (strainer) for an easy source of water sucked dirt.

Pump Installation

tb-pompa-oktb-pompa-bad

Price PINGUIN TANK

: CALL

Dapatkan penawaran terbaik untuk
PINGUIN TANK !

Nama
Quantity
Unit
Request Quote

Other Related Products From Toko Sinar Surya Bali

We are an Online Media that consists of Distributors, Resellers, Manufactures, Suppliers, importers and exporters. If you are interested to buy PINGUIN TANK cheap, please contact the Company directly.

If you are a Company who wished to sell your product,
Contact Supplier
Sinar Surya Bali

6 Year
Response Rate :
50%
Jl Gatot Subroto Barat 412 Denpasar Bali , Indonesia Denpasar, Bali - Indonesia

Other Companies Related to Sinar Surya Bali

PT. Tirta Amertha

Verified Supplier
Indotrading gold member
1 Year
Response Rate 100%

CV. Toya Arta Sejahtera

Verified Supplier
Indotrading gold member
1 Year
Response Rate 100%

PT PROCHEM MULIA SEJATI

Verified Supplier
Indotrading gold member
1 Year
Response Rate 100%
Arrow