Star-delta Timer H3DK-G

Rp1
  • Minimum Order 1 unit
  • stock212
  • Country Origin Indonesia
  • CategoriesTimer
  • Last Updated25 Aug 2016

Product Specification Star-delta Timer H3DK-G

Star-delta Timer H3DK-G

DIN Track-mounted, 22.5 mm Standard-width-Timer Series



Features:

Set of two time ranges between 1 and 120 s with a one-Timer.

Models with 240 to 440-VAC power supply added to the series.

Specifications:

& nbSP;

Time Ranges

Time range settings t1x1 t1x10
Star time (t1) set range of 1 to 12 s 10 to 120 s

Star-Delta transfer time (t2) Select from 0.05, 0.1, 0.25, or 0.5 s.

Rating:

H3DK-G, H3DK-GA-GE
Power supply voltage * 1 24 to 240 VAC/DC, 50/60 Hz * 2
12 VDC * 2 240 to 440 VAC (50/60 Hz) * 6
Allowable voltage fluctuation range 24 to 240 VAC/DC: 85% to 110% ofrated voltage
12 VDC: 90% to 110% of rated voltage of 80% to 110% of rated voltage
Power reset Minimum power-OFF time: 0.5 s
Reset voltage 10% of rated voltage
Power
consumption H3DK-G At 240 VAC: 6.5 VA max. * 3 At 440 VAC: 34 VA max.
H3DK-GA At 12 VDC: 0.9 W max.
Control output Contact output (Time-limit output: relay output: SPDT, Star,
Delta output: SPDT):
5 A at 250 VAC resistive load with (cosΦ = 1)
5 A at 24VDC with resistive load * 3, * 4 Ith 2 A
AC-15 120 VAC: 1.5 A
AC-15 240 VAC: 1 A
AC-15 440 VAC: 0.3 A
Ambient operating temperature-20 to 55 ° C (with no icing)
Storage temperature-40 to 70 ° C (with no icing)
Ambient operating humidity 25% to 85%

* 1. When using a 24-VDC power supply voltage, there will be an inrush current of approximately 0.25 a. Allow for this inrush current when turning ON and OFF the power supply to the TeamER with device with a solid-state output, such as a sensor.

* 2 DC ripple: 20% max.

* 3. Refer to the DC Power Consumptions (Reference Information) on the Data Sheet for DC power consumptions.

* 4 The control output ratings are for one H3DK operating alone. If you operate two or more Timers side by side, refer to the Installation Pitch and Output Switching Capacity (ReferenceValues) in the below.

* VDC 5,125:0.15 A max. with resistive load, 125 VDC: 0.1 A with L/R of 7 ms.
Minimum load: 10 mA at 5 VDC (P level, reference value)

6. * For the H3DK-GE, approx. 6 A of inrush current will flow when the power supply is turned ON. When selecting the device connected to the Timer, allow leeway in the current ratings.

>
Characteristics

H3DK-G, H3DK-GA-GE
Accuracy of operating
time of approximately 1% of FS max.
Setting error ± 10% of FS ± 0.05 s max.
Transfer time Total error ± (25% of the transfer time + 5 ms) max.
Influence of voltage ± 0.5% of FS max.
Influence of temperature of ± 2% FS max.
Insulation resistance 100 MΩ at 500 VDC min.
Dielectric strength Between current-carrying metal parts and exposed
non-current-carrying metal parts: 2.000 VAC 50/60
Hz for 1 min.
Between control output terminals and operating
circuit: 2.000 VAC 50/60 Hz for 1 min.
Between contacts not located next to each other:
1.000 VAC 50/60 Hz for 1 min. Between current-carrying metal parts and exposed
non-current-carrying metal parts: 2.500 VAC 50/60
Hz for 1 min.
Between control output terminals and operating
circuit: 2,500 VAC 50/60 Hz for 1 min.
Between contacts not located next to each other:
1.000 VAC 50/60 Hz for 1 min.
Impulse withstand
voltage: H3DK-G
24 to 240 VAC/VDC: 3 kV between power terminals,
4.5 kV between current-carrying metal parts and
exposed non-metal parts currentcarrying
H3DK-GA:
12 VDC: 1 kV between power terminals, 1.5 kV
between current-carrying metal parts and exposed
non-current-carrying metal partss ---
Noise immunity Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise): ± 1.5 kV *
Static immunity Malfunction: 4 kV, Destruction: 8 kV
Vibration
resistance Destruction 0.75-mm single amplitude at 10 to 55 Hz for 2 h each in 3 directions
Malfunction 0.5-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Shock
resistance Destruction 1.000 m/s2 3 times each in 6 directions
Malfunction 100 m/s2 3 times each in 6 directions
Life
expectancy Mechanical 10 million operations min.
(under no load at 1.800 operations/h) 10 million operations min.
(under no load at 1.800 operations/h)
Electrical 100.000 operations min.
(5 A at 250 VAC resistive load, at 360 operations/h) 100.000 operations min.
(0.2 A at 440 VAC, resistive load at 1.800 operations/h)
Degree of protection IP30 (Terminal block: IP20)
Weigh

Price Star-delta Timer H3DK-G

: Rp1

Dapatkan penawaran terbaik untuk
Star-delta Timer H3DK-G !

Nama
Quantity
Unit
Request Quote

Other Related Products From PT. Taharica

Cracktronic
Hardness Tester

Ti-1071.
Other Measurement Tools

D-2020.
Thickness Gauge

AIR CONDITIONING-US TR 108
Weighing Scales

Rp 1

Ex-Series.
Durometer

We are an Online Media that consists of Distributors, Resellers, Manufactures, Suppliers, importers and exporters. If you are interested to buy Star-delta Timer H3DK-G cheap, please contact the Company directly.

If you are a Company who wished to sell your product,
Contact Supplier
Taharica

Response Rate :
100%
Jl. Radin Inten II No. 62 Duren Sawit Jakarta Timur, DKI Jakarta - Indonesia

Other Companies Related to Taharica

Hargo Mandiri

Verified Supplier
Indotrading gold member
1 Year
Response Rate 100%

PT. Hamoda Tools

Verified Supplier
Indotrading gold member
1 Year
Response Rate 100%

PT Oscar Tunastama (www.distributorhager.com)

Verified Supplier
Indotrading gold member
1 Year
Response Rate 100%
Arrow