Evolution 260 Bio Spectrophotometer plus Tablet Control Module
Full specifications
Accuracy ( Photometric ) 1A : ±0.006A
2A : ±0.010A
Measured at 440 nm using calibrated neutral density filters traceable to NIST
Baseline Flatness ±0.0010A, 200-800 nm, 1.0 nm SBW, smoothing
Beam Geometry Double-beam with Application Focused Beam Geometry
Certifications/Compliance ISO 9001:2008
Data Interval 10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
Description Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International
Detector Type Dual Silicon Photodiodes
Dimensions ( L x W x H ) 62.2 x 48.6 x 27.9 cm
Display Touchscreen LCD panel; 800 x 480; 17.8 cm ( 7 in. Diagonal )
Drift <0.0005 A/hr, 500 nm, 1.0 nm SBW, 1 hr warm-up
Electrical Requirements 100-240 V 50-60 Hz selected automatically 150 W maximum
Item Description Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International
Keypad Sealed membrane
Lamp Xenon Flash Lamp, 3-year warranty ( 7 years typical lifetime )
Noise 0A : <0.00015A
1A : <0.00025A
2A : <0.00080A
260 nm, 1.0 nm SBW, RMS
Operating System Microsoft Windows™ XP embedded
INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument
Optical Design Double Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing ( Guaranteed Performance Specifications )
Resolution ( toluene in Hexane ) : ≥1.8A
Photometric Accuracy ( 60 mg/L K2Cr2O7 ) : ±0.010A
Stray Light : ≤1 %T at 198 nm : KCI; ≤0.05 % AT at 220 nm : Nal, KI
Wavelength Accuracy : ±0.5 nm 541.9, 546.1 nm Hg emission lines, ±0.8 nm full range
Wavelength Repeatability : ≤0.05 nm, repetitive scanning of 546.1 nm Hg emission line
Photometric Accuracy Instrument 1A : ±0.006A
2A : ±0.010A
Measured at 440 nm using calibrated neutral density filters traceable to NIST
Photometric Display -0.3 - 4.0A
Photometric Range >3.5A
Photometric Repeatability ±0.0002A
Scan Ordinate Modes Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log ( 1/R ), log ( Abs ), Abs*Factor, Intensity
Scan Speed <1-6000nm/min, variable
Spectral Bandwidth Variable : 1.0 nm; 2.0 nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized
Type Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International
Wavelength Accuracy ±0.5 nm ( 541.9, 546.1 nm mercury lines )
±0.8 nm ( full range 190-1100 nm )
Wavelength Range 190 - 1,100 nm
Wavelength Scan Speed <1 to 6,000 nm/min; variable
Weight ( Metric ) 14.4 kg
Catalog Number 912A0888
Evolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes power cords
Full specifications
Accuracy ( Photometric ) 1A : ±0.006A
2A : ±0.010A
Measured at 440 nm using calibrated neutral density filters traceable to NIST
Baseline Flatness ±0.0010A, 200-800 nm, 1.0 nm SBW, smoothing
Beam Geometry Double-beam with Application Focused Beam Geometry
Certifications/Compliance ISO 9001:2008
Data Interval 10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm
Description Evolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
Detector Type Dual Silicon Photodiodes
Dimensions ( L x W x H ) 62.2 x 48.6 x 27.9 cm ( 24 x 19 x 11 in )
Drift <0.0005 A/hr, 500 nm, 1.0 nm SBW, 1 hr warm-up
Electrical Requirements 100-240 V 50-60 Hz selected automatically 150 W maximum
Lamp Xenon Flash Lamp, 3-year warranty ( 7 years typical lifetime )
Noise 0A : <0.00015A
1A : <0.00025A
2A : <0.00080A
260 nm, 1.0 nm SBW, RMS
Operating System Microsoft Windows 7, Windows 8
Optical Design Double Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing ( Guaranteed Performance Specifications )
Resolution ( toluene in Hexane ) : ≥1.8A
Photometric Accuracy ( 60 mg/L K2Cr2O7 ) : ±0.010A
Stray Light : ≤1 %AT at 198 nm: KCI; ≤0.05 %AT at 220 nm : Nal, KI
Wavelength Accuracy : ±0.5 nm 541.9, 546.1 nm Hg emission lines, ±0.8 nm full range
Wavelength Repeatability : ≤0.05 nm, repetitive scanning of 546.1 nm Hg emission line
Photometric Accuracy Instrument 1A : ±0.006A
2A : ±0.010A
Measured at 440 nm using calibrated neutral density filters traceable to NIST
Photometric Display -0.3 - 4.0A
Photometric Range >3.5A
Photometric Repeatability ±0.0002A
Scan Ordinate Modes Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log ( 1/R ), log ( Abs ), Abs*Factor, Intensity
Scan Speed <1-6000 nm/min, variable
Spectral Bandwidth Variable : 1.0 nm; 2.0 nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized
Type Evolution 260 Bio UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords
Wavelength Accuracy ±0.5 nm ( 541.9, 546.1 nm mercury lines )
±0.8 nm ( full range 190-1100 nm )
Wavelength Range 190 to 1100 nm
Wavelength Scan Speed <1 to 6000 nm/min; variable
Weight ( English ) 32 lb
Weight ( Metric ) 14.4 kg
Catalog Number 840-211000