Sell Amplifier Unit Main Unit NPN LV 11SB from Indonesia by CV. Globalindo Internusa,Cheap Price

Amplifier Unit Main Unit NPN LV 11SB

Rp123
  • Minimum Order 1 1
  • CategoriesLaser Sensors
  • Last Updated24 Sep 2018

Product Specification Amplifier Unit Main Unit NPN LV 11SB

Laser Sensors

Sale Amplifier Unit Main Unit NPN LV 11SB 

Model

LV-11SB*1

Type

Main unit

Output

NPN

Control output

NPN open-collector x 2 ch 40 VDC max. 100 mA max. per output

Response time

ExceptLV-S31

ULTRA

4 ms

SUPER

2 ms

TURBO

500 µs

FINE

250 µs

HSP

80 µs

LV-S31standard mode

500 µs

LV-S31standard mode

SPED2

2 ms

SPED3

8 ms

SPED4

32 ms

LV-S31High-speed mode

250 µs

Control input

Light emission stop input, external calibration, set value bank selection input, or shift input

Number of interference prevention units

ULTRA

4*2

SUPER

TURBO

2*2

FINE

HSP

0*2

Unit expansion

Up to 16 expansion units can be installed (17 units including the main unit)*3

Rating

Power voltage

12 to 24 VDC, Ripple (P-P) 10 % or less, Class2*4

Power consumption

Normal

1.7 W max. (70 mA max. for 24 V)

Ratings

Eco-Half Eco-All

1.55 W max. (65 mA max. for 24 V)

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*5

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Main unit

Main body, cover: Polycarbonate

Weight

Approx. 80 g (including 2 m 6.6' cable)

*1 LV-S62 and LV-S63 can ONLY be used with amplifiers ending with B or BP.
*2 Numbers for the LV-S31 are four in standard mode and two in high-speed mode.
*3 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows:
1 to 2 units connected: -10 to +55ºC 14 to 131ºF
3 to 10 units connected: -10 to +50ºC 14 to 122ºF
11 to 16 units connected: -10 to +45ºC 14 to 113ºF
*4 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % or less
*5 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C 14 to 131°F, 3 to 10 units connected: -10 to +50 °C 14 to 122°F, 11 to 16 units connected: -10 to +45 °C 14 to 113°F

Price Amplifier Unit Main Unit NPN LV 11SB

: Rp123
The company is engaged in general suppliers and contractors who sell Fence Ornaments, Carpentry / Plantation Equipment, Fogging Drugs, Kitchen Equipment / Equipments. We are located in Jakarta & Surabaya

We Sell
  • Ornamen Pagar
  • Peralatan/ Perlengkapan Dapur
  • Peralatan Pertukangan/ Perkebunan
  • Alat
  • Obat Fogging
  • Alat Musik

Dapatkan penawaran terbaik untuk
Amplifier Unit Main Unit NPN LV 11SB !

Nama
Quantity
Unit
Request Quote
We are an Online Media that consists of Distributors, Resellers, Manufactures, Suppliers, importers and exporters. If you are interested to buy Amplifier Unit Main Unit NPN LV 11SB cheap, please contact the Company directly.

If you are a Company who wished to sell your product,
Contact Supplier
Globalindo Internusa

2 Year
Response Rate :
84%
Jl. Rambutan 8/ 47 Komplek Perumahan Pondok Candra Indah, Waru - Sidoarjo Sidoarjo, Jawa Timur - Indonesia
Arrow