AC Current Detection Relay

Product Specification AC Current Detection Relay

Browse through the extensive list of Current Relay. Shop online for otherHokkim available at Moglix in the lowest price range.

AIR CONDITIONING under Current Relay DUC-2 (0-2Amp)

The DUC-2 monitors alternating current. Its setting is adjustable from zero to 2 .0a. The current circuit is
connected to terminals S1 and S2 either directly or through current transformers.
The DUC-2 is designed to sense under current. When the measured current is above the setting, an
the internal relay will energize and the green Up the LED comes ON while the red LED Trip is OFF. If the
current drops below the settiNG, the relay releases and the green LED goes OFF while Up the red Trip
The LED comes ON. Contacts 11-14 close Up in the condition and open in the Trip or No Supply condition.
Technical Data
Supply Voltage: 240VAC ❑ ❑ 115VAC
❑ ❑ 12VDC 24VDC
Frequency: 50 ~ 60 Hz
Consumption: 2VA Voltage Circuit
: 1VA Current Circuit
On/TRIP Hysteresis: 2% of rated
Current Adjustment: 0-2A
Indication: Green LED (Up)
Red LED (Trip)
Dielectric Strength Between: Current Voltage Circuit &: 3 kV
Output Voltage Circuit &: 2 kV
Output Contacts: 2 kV
Output Contacts: 5A 240V 50 Hz AC1
The relay Up Close; 11-14 11-12 Open;
The relay Trip 11-14 Open-Close 11-12;

 

AIR CONDITIONING under Current Relay DUC-2D

AIR CONDITIONING Under Current Relays (0-2A) with Delay
Utilization:
The DUC-2D monitors alternating current. Its current setting is adjustable from zero to 2 .0a andthe
delay setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either
directly or through current transformers.
The DUC-2D is designed to sense under current. When the measured current is above the setting, an
the internal relay will energize and the green Up the LED comes ON while the Amber Delay LED and the red
Trip LED'S are OFF. If the current drops below the setting, the Amber Delay LED comes ON; then after
theset delay, the relay releases and the green LED goes OFF while Up the red LED comes ON Trip.
Technical Data
Supply Voltage: 240VAC ❑ ❑ 115VAC
❑ ❑ 12VDC 24VDC
Frequency: 50 ~ 60 Hz
Consumption: 2VA Voltage Circuit
: 1VA Current Circuit
On/TRIP Hysteresis: 2% of rated
Current Adjustment: 0-2A
Delay Adjustment: 0-20 Sec
Indication: Green LED (Up)
Amber LEDS (Delay)
Red LED (Trip)
Dielectric Strength Between: Current Voltage Circuit &: 3 kV
Output Voltage Circuit &: 2 kV
Output Contacts: 2 kV
Output Contacts: 5A 240V 50 Hz AC1
The relay Up Close; 11-14 11-12 Open
The relay Trip 11-14 Open-Close 11-12;

AIR CONDITIONING Under Current Relays (0-2A) with 2 Contacts DUC2-2
Utilization:
The DUC2-2 monitors alternating current. Its setting is adjustable from zero to 2 .0a. The current circuit
is connected to terminals S1 and S2 either directly or through current transformers.
The DUC2-2 is designed to sense under current. When the measured current is above the setting, two
internal relays will energize and the green Up the LED comes ON while the red LED Trip is OFF. If the
current drops below the setting of the relays, the release and the green LED goes OFF while Up the red Trip
The LED comes ON. Contacts 11-14 & 21-24 close Up in the condition and open in the Trip or No Supply
condition.
TechnicalData
Supply Voltage: 240VAC ❑ ❑ 115VAC
Frequency: 50 ~ 60 Hz
Consumption: 2VA Voltage Circuit
: 1VA Current Circuit
On/TRIP Hysteresis: 2% of rated
Current Adjustment: 0-2A
Indication: Green LED (Up)
Red LED (Trip)
Dielectric Strength Between:
Current Voltage Circuit &: 3 kV
Output Voltage Circuit &: 2 kV
Output Contacts: 2 kV
Output Contacts: 5A 240V 50 Hz AC1
The Relay Up
11-14 Close
11-12 Open
21-24 Close
21-22 Open
The Relay Trip
11-14 Open
11-12 pm Close
21-24 Open
21-22 Close

AIR CONDITIONING Under Current Relays (0-2A) with Contacts and 2 Delay Type DUC2-2D

Utilization:
The DUC2-2D monitors alternating current. Its current setting is adjustable from zero to 2 .0a and the
delay setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either
/> directly or through current transformers.
The DUC2-2D is designed to sense under current. When the measured current is above the setting, two
internal relays will energize and the green Up the LED comes ON while the Amber Delay LED and the red
Trip LED'S are OFF. If the current drops below the setting, the Amber Delay LED comes ON; then after
the set delay relays, the release and the green LED goes OFF while Up the red LED comes ON Trip.
Contacts 11-14 & 21-24 close Up in the condition and open in the Trip or No Supply condition.
Technical Data
Supply Voltage: 240VAC ❑ ❑ 115VAC
❑ ❑ 12VDC 24VDC
Frequency: 50 ~ 60 Hz
Consumption: 2VA Voltage Circuit
: 1VA Current Circuit
On/TRIP Hysteresis: 2% of rated
Current Adjustment: 0-2A
Delay Adjustment: 0-20 Sec
Indication: Green LED (Up)
Amber LEDS (Delay)
Red LED (Trip)
Dielectric Strength Between:r/> Current Voltage Circuit &: 3 kV
Output Voltage Circuit &: 2 kV
Output Contacts: 2 kV
Output Contacts: 5A 240V 50 Hz AC1
The Relay Up
11-14 Close
11-12 Open
21-24 Close
21-22 Open
The Relay Trip
11-14 Open
11-12 pm Close
21-24 Open
21-22 Close

AIR CONDITIONING Under Current Relays (0-5A) Model DUC-5
Utilization:
The DUC-5 monitors alternating current. Its setting is adjustable from zERO to 5.0 a. The current circuit
is connected to terminals S1 and S2 either directly or through current transformers.
The DUC-5 is designed to sense under current. When the circuit current is above the setting, an internal
the relay will energize and the red LED Trip goes OFF while the green LED comes ON Up. If the current
drops below the setting, the relay releases and the red LED comes ON the Trip while the green LED goes Up
Off. 11-14 close contacts in the Up condition and open in the Trip or No Supply condition.
Technical Data
Supply Voltage: 240VAC ❑ ❑ 115VAC
❑ ❑ 12VDC 24VDC
Frequency: 50 ~ 60 Hz
Consumption: 2VA Voltage Circuit
: 1VA Current Circuit
On/TRIP Hysteresis: 3% of rated
Current Adjustment: 0-5A
Indication: Green LED (Up)
Red LED (Trip)
Dielectric Strength Between:
Current Voltage Circuit &: 3 kV
Output Voltage Circuit &: 2 kV
Output Contacts: 2 kV
Output Contacts: 5A 240V 50 Hz AC1
The Relay Up
11-14 Close
11-12 Open
The Relay Trip
11-14 Open
11-12 pm Close

AIR CONDITIONING Under Current Relays (0-5A) with Delay model of DUC-5 d
Utilization:
The DUC-5 d monitors alternating current. Its current setting is adjustable from zero to 5A and the delay
the setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either
directly or through current transformers.
The DUC-5 d is designed to sense under current. When the measured current is above the setting, an
the internal relay will energize and the green Up the LED comes ON while the Amber Delay LED and the red
Trip LED'S are OFF. If the current drops below the setting, the Amber Delay LED comes ON; then after
the set delay, the relay releases and the green LED goes OFF while Up the red LED comes ON Trip.
Technical Data
SuppLY Voltage: 240VAC ❑ ❑ 115VAC
❑ ❑ 12VDC 24VDC
Frequency: 50 ~ 60 Hz
Consumption: 2VA Voltage Circuit
: 1VA Current Circuit
On/TRIP Hysteresis: 2% of rated
Current Adjustment: 0-5A
Delay Adjustment: 0-20 Sec
Indication: Green LED (Up)
Amber LEDS (Delay)
Red LED (Trip)
Dielectric Strength Between:
Current Voltage Circuit &: 3 kV
Output Voltage Circuit &: 2 kV
Output Contacts: 2 kVBr/> Output Contacts: 5A 240V 50 Hz AC1
The Relay Up
11-14 Close
11-12 Open
The Relay Trip
11-14 Open
11-12 pm Close

AIR CONDITIONING Under Current Relays (0-10A) Model DUC-10
Utilization:
The DUC-10 monitors alternating current. Its setting is adjustable from zero to 10A. The current circuit
is connected to terminals S1 and S2 either directly or through current transformers.
The DUC-10 is designed to sense under current. When tHe circuit current is above the setting, an internal
the relay will energize and the red LED Trip goes OFF while the green LED comes ON Up. If the current
drops below the setting, the relay releases and the red LED comes ON the Trip while the green LED goes Up
Off. Contacts 11-14 close Up in the condition and open in the Trip or No Supply condition.
Technical Data
Supply Voltage: 240VAC ❑ ❑ 115VAC
❑ ❑ 12VDC 24VDC
Frequency: 50 ~ 60 Hz
Consumption: 2VA Voltage Circuit
: 1VA Current Circuit
On/TRIP Hysteresis: 2% of rated
Current Adjustment: 0-10A
Indication: Green LED (Up)
Red LED (Trip)
Dielectric Strength Between:
Current Voltage Circuit &: 3 kV
Output Voltage Circuit &: 2 kV
Output Contacts: 2 kV
Output Contacts: 5A 240V 50 Hz AC1
The relay Up Close; 11-14 11-12 Open
The relay Trip 11-14 Open-Close 11-12;

AIR CONDITIONING Under Current Relay (0-5A) with 2 Contacts Model DUC2-5
Utilization:
The DUC2-5 monitors alternating current. Its setting is adjustable from zero to 5.0 a. The current circuit
is connected to terminals S1 and S2 either directly or through current transformers.
The DUC2-5 is designed to sense under current. When the circuit current is above the setting, two
internal relays will energize and the red LED Trip goes OFF while the green LED comes ON Up. If the
current drops below the setting, the relays release and the red LED comes ON the Trip while the green Up
The LED goes OFF. Contacts 11-14 & 21-24 close Up in the condition and open in the Trip or No Supply
condition.
Technical Data
Supply Voltage: 240VAC ❑ ❑ 115VAC
❑ ❑ 12VDC 24VDC
Frequency: 50 ~ 60 Hz
Consumption: 2VA Voltage Circuit
: 1VA Current Circuit
On/TRIP Hysteresis: 2% of rated
Current Adjustment: 0-5A
Indication: GreenLed (Up)
Red LED (Trip)
Dielectric Strength Between:
Current Voltage Circuit &: 3 kV
Output Voltage Circuit &: 2 kV
Output Contacts: 2 kV
Output Contacts: 5A 240V 50 Hz AC1
The Relay Up
11-14 Close
11-12 Open
21-24 Close
21-22 Open
The Relay Trip
11-14 Open
11-12 pm Close
21-24 Open
21-22 Close

AIR CONDITIONING Under Current Relays (0-5A), with the Contacts and 2 Delay Model DUC2-5 d

/> Utilization:
The DUC2-5 d monitors alternating current. Its current setting is adjustable from zero to 5A and the delay
the setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either
directly or through current transformers.
The DUC2-5 d is designed to sense under current. When the measured current is above the setting, two
internal relays will energize and the green Up the LED comes ON while the Amber LED and Delay tHe red
Trip LED'S are OFF. If the current drops below the setting, the Amber Delay LED comes ON; then after
the set delay relays, the release and the green LED goes OFF while Up the red LED comes ON Trip.
Contacts 11-14 & 21-24 close Up in the condition and open in the Trip or No Supply condition.
Technical Data
Supply Voltage: 240VAC ❑ ❑ 115VAC
❑ ❑ 12VDC 24VDC
Frequency: 50 ~ 60 Hz
Consumption: 2VA Voltage Circuit
: 1VA Current Circuit
On/TRIP Hysteresis: 2% of rated
Current Adjustment: 0-5A
Delay Adjustment: 0-20 Sec
Indication: Green LED (Up)
Amber LEDS (Delay)
Red LED (Trip)
Dielectric Strength Between:
Current Voltage Circuit &: 3 kV
Output Voltage Circuit &: 2 kV
Output Contacts: 2 kV
Output Contacts: 5A 240V 50 Hz AC1
The Relay Up
11-14 Close
11-12 Open
21-24 Close
21-22 Open
The Relay Trip
11-14 Open
11-12 pm Close
21-24 Open
21-22 Close

AIR CONDITIONING Under Current Relays (0-8A) with the Contacts and 2 Delay Model DUC2-8 d
Utilization:
The DUC2-8 d monitors alternating current. Its current setting is adjustable from zero to 8A and the delay
the setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either
directly or through current transformers.
The DUC2-8 d is designedto sense under current. When the measured current is above the setting, two
internal relays will energize and the green Up the LED comes ON while the Amber Delay LED and the red
Trip LED'S are OFF. If the current drops below the setting, the Amber Delay LED comes ON; then after
the set delay relays, the release and the green LED goes OFF while Up the red LED comes ON Trip.
Contacts 11-14 & 21-24 close Up in the condition and open in the Trip or No Supply condition.

> HOKKIM
giving you control Control & Protection Relays
DUC2-8 d
AIR CONDITIONING Under Current
Relay
12 14 11 21 24 22
8
2 6
4
4
8 12
16
20
Delay
Technical Data
Supply Voltage: 240VAC ❑ ❑ 115VAC
❑ ❑ 12VDC 24VDC
Frequency: 50 ~ 60 Hz
Consumption: 2VA Voltage Circuit
: 1VA Current Circuit
On/TRIP Hysteresis: 2% of rated
Current Adjustment: 0-8A
Delay Adjustment: 0-20 Sec
Indication: Green LED (Up)
Amber LEDS (Delay)
Red LED (Trip)
Dielectric Strength Between:
Current Voltage Circuit &: 3 kV
Output Voltage Circuit &: 2 kV
Output Contacts: 2 kV
Output Contacts: 5A 240V 50 Hz AC1
The relay Up Close 11-14
11-12 Open
21-24 Close
21-22 Open
The relay Trip 11-14 Open
11-12 pm Close
21-24 Open
21-22 Close

AC Over Current Relay (0-2A) Model DOC-2
Utilization:
The DOC-2 monitors alternating current. Its setting is adjustable from zero to 2 .0a. The current circuit
is connected to terminals S1 and S2 either directly or through current transformers.
The DOC-2 is designed to sense over current. When the measured current is below the setting, an internal
the relay will energize and the green Up the LED comes ON while the red LED Trip is OFF. If the current rises
above the settings, the relay releases and the green LED goes OFF while Up the red LED comes ON Trip.
Contacts 11-14 close Up in the condition and open in the Trip or No Supply condition.
Technical Data
Supply Voltage: 240VAC ❑ ❑ 115VAC
❑ ❑ 12VDC 24VDC
Frequency: 50 ~ 60 Hz
Consumption: 2VA Voltage Circuit
: 1VA Current Circuit
On/TRIP Hysteresis: 2% of rated
Adjustment: 0-2A
Indication: Green LED (Up)
RedLed (Trip)
Dielectric Strength Between:
Current Voltage Circuit &: 3 kV
Output Voltage Circuit &: 2 kV
Output Contacts: 2 kV
Output Contacts: 5A 240V 50 Hz AC1
The relay Up Close 11-14; 11-12 Open
The relay Trip 11-14 Open; 11-12 pm Close

AC Over Current Relay (0-2A) with Delay Model DOC2-2D
Utilization:
The DOC-2D monitors alternating current. Its current setting is adjustable from zero to 2 .0a and the
delay settING is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either
directly or through current transformers.
The DOC-2D is designed to sense over current. When the measured current is below the setting, an
the internal relay will energize and the green Up the LED comes ON while the Amber Delay LED and the red
Trip LED'S are OFF. If the current rises above the setting, the Amber Delay LED comes ON; then after the
set delay, the relay releases and the green LED goes OFF while Up the red LED comes ON Trip.
Technical Data
Supply Voltage: 240VAC ❑ ❑ 115VAC
❑ ❑ 12VDC 24VDC
Frequency: 50 ~ 60 Hz
Consumption: 2VA Voltage Circuit
: 1VA Current Circuit
On/TRIP Hysteresis: 2% of rated
Current Adjustment: 0-2A
Delay Adjustment: 0-20 Sec
Indication: Green LED (Up)
Amber LEDS (Delay)
Red LED (Trip)
Dielectric Strength Between:

Product Image
AC Current Detection Relay 1
Want to buy this product ?
Get the best prices from supplier
Request Quote
Company Detail
Since
2011
Company field
IGBT, Noise Filter, SSR, Electronik, Electrik
Number of employees
2011
We sell
Solid State Relay,NOISE FILTER,Thyristor,DIODA,IGBT,POWER SUPPLY
Company profile
We is a company engaged in the sale of such SSR modules, Thyristor, IGBT, Noise Filters, Diodes, Power Supply, HMI, Inverter, PLC, Photo Electric Sensor, Proximity Switch and Instrument Control product sharing. these products our stockist and we import from China, Hong Kong, Italy, Singapore. we believe can provide the best prices to our clientele

Want to buy AC Current Detection Relay ?
Get the best price by clicking the request quote button !

Nama
Quantity
Unit
Request Quote

Other Related Products From PT Mandiri Raya Tangguh

AC Current Detection Relay Phase Failure & Sequence Relay
CALL
Category
Brand
hokkim
Update
05 Jun 2018
Min Order
1
AC Voltage Protection Relay
CALL
Category
Brand
hokkim
Update
05 Jun 2018
Min Order
1
Relay Releco
CALL
Category
Brand
releco
Update
09 Jun 2021
Min Order
1
Solid State Relay Ss301-3Z-D3 Merk Fuji Electric
CALL
Category
Brand
Fuji Electric
Update
29 Oct 2014
Min Order
1
Solid State Relay Ssr Model Ss502e-3Z-D3 Merk Fuji Electric
CALL
Category
Brand
Fuji Electric
Update
29 Oct 2014
Min Order
1
Arrow