Incinerator/Insinerator/Mesin Pembakar Sampah
Incinerator Kapasitas Ruang Bakar 0,017 M³
Kapasitas 2.25 to 3.75 kg/jam
Dimensi ruang bakar : 35 x 35 x 41 cm = 0.05m3
Burner : 1 Unit
Blower : 1 Unit
Fuel : Solar / Kerosene
Fuel Consumption : 4 Liter / hour
Electricity Consumption : 250 Watt
Voltage : 220 V / 1 Phaze / 50 Hz
Control Panel : Digital
Constru
ction in Wall:
● Fire SK34/SK36 Brick
● Castabel C-16
● Insulation Brick C-1
● Ceramic Fiber Blanket
● Air Setting Mortars.
Burning Room temperature: 600 ° C-1000 ° C
Size (WxHxT): 600 x 600 x 900 mm
Chimney: 5 m-6 m
Fuel Tank: 40 Litres
Weight: ± 300 Kg
Incinerator combustion chamber capacity 0,1 m³ = 15 kg/h
Or capacity 0,1 x 150 kg/m³= 10 to 15 kg/h
Outer dimension (±): 110 x 80 x 100 cm
Combustion chamber dimensions: 63 x 64 x 80 cm = 0.3 m3
The main Combustion burner: 1 piece
Blower/capacity: 1 piece/2.5 "
Fuel: Kerosene/Diesel
Burner consumption: ± 5 litres/hour
Electricity consumption: ± 650 Watt
Input Voltage: 220V/1 Phase/50 Hz
Control Panel/Automatic, Timer: 0-120 minutes
Brick Wall Construction In:
● Fire SK34/SK36 Brick
● Castabel C-16
● Insulation Brick C-1
● Ceramic Fiber Blanket
● Air Setting Mortars.
Outer wall: MS. Plate 3 mm
Burning Room temperature: 600 ° C-1000 ° C
Chimney/high (±): F 25 cm x 4 m
Fuel tank: ± 60 litres
Water pump: approximately 20-40 litres/minute
Water discharge: ± 40 litres/minute
Total weight: ± 850 kg
r/>
Incinerator capacity combustion chamber 0.17 m³ = 25 kg/hour
Or capacity 0,1 x 150 kg/m³ = 17 to 25 kg/h
Outer dimension (±): 120 x 100 x 120 cm
Combustion chamber dimensions: 80 x 75 x 95cm = 0.57 m3
The main Combustion burner: 1 piece
Blower/capacity: 1 piece/2.5 "
Fuel: Kerosene/Diesel
Burner consumption: ± 10 liters/hour
Electricity consumption: ± 750 Watt
Input Voltage: 220V/1 Phase/50 Hz
Control Panel/Automatic, Timer: 0-120 minutes
Brick Wall Construction In:
● Fire SK34/SK36 Brick
● Castabel C-16
● Insulation Brick C-1
● Ceramic Fiber Blanket
● Air Setting Mortars.
Outer wall: MS. Plate 3 mm
Burning Room temperature: 600 ° C-1000 ° C
Chimney/high (±): F 25 cm x 4 m
Fuel tank: ± 60 litres
Water pump: approximately 20-40 litres/minute
Water discharge: ± 40 litres/minute
Total weight: CA. 1.100 kg
Incinerator capacity of 20-30 kg/h
Type of waste Bulk density: ± 0.1 – 0.15 kg/dm3
Infectious and Industrial waste
Incineration Capacity: 30 kg/hour (0,3 m3/hour), Multiple Chamber, Retort system
Operation Time: 8 hour/day
Chamber Volume:
-First Chamber 0.7 m3
-Mixing Room 0.1 m3
-Second Chamber 0.3 m3
Incinerator dimention L1, 8 m x 2 m x H1, W1, 6 mm
Burner
-First Chamber Burner: 5 – 10 litres/h Gun (Oil Burner)
-Second Chamber Burner: 5 – 10 litres/h Gun (Oil Burner)
Chamber Temperature
-1st Chamber 600-1000 DegC
-2nd Chamber 600-1000 DegC
Chamber Pressure: negative (under atmosferic pressure)
Exhaust Stack (chimney): Height 8 meters
Insulation lined with castable &Glasswool (for 1 St stack)
Refractory construction
-Fire Brick
-Castable
Chamber Insulation
-1st: Fire brick wall
-2nd wall: Ceramic fibre
-3rd wall: Rockwool
-4th wall: Glasswool
-5th: Shell wall plate
-Bottom insulating: insulating Brick
Shell Material: Structure & Mild steel
Centrifugal blower: (6-12 mm Aq), 14 m3/min, 2 units
Electric Power Requirement: 1 kW/380 V/1 ~/50 Hz
Fuel: Diesel oil (Diesel)/Kerosene (kerosene)
Fuel Consumption: Max. 20 litres/hour
Fuel Tank Capacity: 200 Liters
Control System: Manual & otomatic (Control Panel)
Ash: 5 – 10% waste weight
Ash Discharging System: Manual
Feeding System: Manual
Warranty: 6 month term (service spare parts &) (excluding transport and accomodation)
Operators Requirement: 1 Person
Area Requirement: 4 x 5 meters
Emision Quality According to Government Regulation
Smokeless, CO< 100="" mg/nm3,="" no2="">< 300="" mg/nm3,="" opacity="">< 10% ="">
Incinerator Capacity 50 kg/hour
Types of Garbage: Bulk density: ± 0.1 – 0.15 kg/m3 Medical Waste
Incinerator capacities: 50 – 65 kg/h (1 m3/h) Multiple Chamber, Retort system
Operating time of 8 hours/day
Combustion Chamber Volume
-Combustion chamber 1: 2.2 m3
Space-Mixing: 0.4 m3
-Combustion chamber 2: 0.9 m3
Dimensions of the PxLxT Incinerator: 2, 2 x 1.96 x 1.6 m
Burner: Gun (Oil Burner)
RB1-Burner: 15-20 litres/hour
RB2-Burner: 15 – 20 litres/hour
The Temperature Of The Combustion Chamber
-1st Chamber: 600 to 1000 ° C
2nd Chamber: 600 to 1000 ° C
Combustion chamber pressure: Negative (below atmospheric pressure)
Exhaust Stack (cerobOng): height 8 meters
Insulation lined with castable & Glasswool
Refraktori construction: Fire Brick and Castable
Combustion Chamber Insulation
Wall-1: Fire brick
-The wall 2: Ceramic fibre
The wall-3: Rockwool
-Wall 4: Glasswool
-5: Shell Wall plate
-Isolation under: Insulating brick
Material Structure: & Sheel Mild steel
Centrifugal blower:: (6 – 12 mmAq), 14m3/min, RB1
Centrifugal (8 – 25 mm Aq), 25 m3/min, RB2
Electrical requirements: 1 kW/380 V/1 ~/50 Hz
Fuel: Diesel oil (Solar)/Kerosene (kerosene)
The Fuel Supply Pipe: Galvanized Pipe
Fuel Consumption: Max. 20 litres/hour
Fuel tank capacity: 200 Liters
Control system: Manual & otomatic (Control Panel)
Ash: 5 – 10% of the weight of the garbage
Ash Disposal System: Manual
Garbage Pengumpanan System: Manual
The needs of the Operator: 1 person
Needs of the area: 5 x 9 meters
The quality of Emissions based on the provisions of the Government:
-Smokeless
-CO< 100="" mg/nm3 ="">
-NO2< 300="" mg/nm3 ="">
-Opacity< 10% ="">
Incinerator capacity of 100 kg/h
Types of Garbage: Bulk density: ± 0.1 – 0.15 kg/m3 Medical Waste
Incinerator capacity: 100 kg/hour (1 m3/h) Multiple Chamber, Retort system
Operating time of 8 hours/day
Combustion Chamber Volume
-Combustion chamber 1: 2,5 m3
Space-Mixing: 0.6 m3
-Combustion chamber 2: 1,2 m3
Dimensions of the PxLxT Incinerator: 3.6 x 1.5 x 1.9 m
Burner: Gun (Oil Burner)
RB1-Burner: 10-15 litres/hour (2 units)
RB2-Burner: 15 – 20 litres/hour
The Temperature Of The Combustion Chamber
-1st Chamber: 600 to 1000 ° C
2nd Chamber:600 to 1000 ° C
Combustion chamber pressure: Negative (below atmospheric pressure)
Exhaust Stack (chimney): height 8 ft daimeter 250 mm
Insulation lined with castable & Glasswool 1st stack
Refraktori construction: Fire Brick and Castable
Combustion Chamber Insulation
Wall-1: Fire brick
-The wall 2: Ceramic fibre
The wall-3: Rockwool
-Wall 4: Glasswool
-5: Shell Wall plate
/>
-Isolation under: Insulating brick
Material Structure: & Sheel Mild steel
Centrifugal blower:: (8 – 25 mmAq), 25 m3/min, RB1
Centrifugal (8 – 25 mm Aq), 25 m3/min, RB2
Electrical requirements: 1 kW/380 V/1 ~/50 Hz
Fuel: Diesel oil (Solar)/Kerosene (kerosene)
The Fuel Supply Pipe: Galvanized Pipe
Fuel Consumption: Max. 35 litres/hour
Fuel tank capacity: 500 Liters
Sisem control: Manual & otomatic (Control Panel)
Ash: 5 – 10% of the weight of the garbage
Ash Disposal System: Manual
Garbage Pengumpanan System: Manual
The needs of the Operator: 1 person
Needs of the area: 6 x 9 meters
The quality of Emissions based on the provisions of the Government:
-Smokeless
-CO< 100="" mg/nm3 ="">
-NO2< 300="" mg/nm3 ="">
-Opacity< 10% ="">
Incinerator Capacity 200 kg/hour
Incinerator Capacity 200 kg/hour, with Manual systems
Incinerator Capacity 200 kg/hour, with a Loading Bucket Elevator System
Types of Garbage Bulk density: ± 0.1 – 0.15 kg/m3 Medical Waste,
Incinerator capacity: 200 kg/h (1 m3/hour), Multiple Chamber, Retort system
Operating time: 8 hours/day
Combustion Chamber Volume
-Combustion chamber 1: 2,5 m3
Space-Mixing: 0.6 m3
-Combustion chamber 2: 1.2 m3
>
Dimensions of Incinerator: P 3.6 m x L 1.5 m x 1.9 m t
Burner
-Burner RB 1: 10 – 15 liters/hour, Gun (Oil Burner) 2 units
-Burner RB 2: 15 – 20 litres/hour, Gun (Oil Burner) 1 unit
The Temperature Of The Combustion Chamber
-1st Chamber: 600-1000 DegC
2nd Chamber: 600-1000 DegC
Combustion chamber pressure: Negative (below atmospheric pressure)
Exhaust Stack (stack):
Height 8 ft Diameter 250 mm
Insulation fact sheetNed with castable & Glasswool for 1st stack
Construction Refraktory
-Fire Brick
-Castable
Combustion Chamber Insulation
Wall-1: Fire brick
-The wall 2: Ceramic fibre
The wall-3: Rockwool
-Wall 4: Glasswool
-5: Shell Wall plate
-Isolation under: Insulating Brick
Material Structure: & Sheel Mild steel
Blower:
Centrifugal (8 – 25 mm Aq): 25 m3/RB, min 1
Centrifugal (8 – 25 mm Aq): 25 m3/min, RB 2
Electrical requirements: 1 kW/380 V/1 ~/50 Hz
:D iesel fuel oil (Diesel)/Kerosene (kerosene)
The Fuel Supply Pipe: Galvanized Pipe
Fuel Consumption: Max. 35 litres/hour
Fuel tank capacity: 500 Liters
Control system: Manual & otomatic (Control Panel)
Ash: 5 – 10% of the weight of the garbage
Ash Disposal System: Manual